Switching Power Supply Troubleshooting Guide!

First of all, you should observe whether the power fuse is damaged. If the fuse is damaged and cannot be replaced eagerly, you must first check the power supply for short circuit. Method: Use the multimeter's electric resistance to test the AC end of the power fuse (test point 1). The normal resistance should be more than tens of kiloohms. If the resistance is zero, it means that there is an AC short circuit in the power supply. In addition, we should also focus on checking whether the AC filter capacitor of the power supply is damaged. If there is a varistor, we should also check this resistance.

If the above test results are normal, we should then test the four rectifier diodes of the power supply (Test Point 2). In the normal state, the forward resistance of the diode is a few k (tested with a multimeter x 1k block), and the reverse resistance is close to infinity. If you find that the test result is abnormal, you need to replace it. After checking down, the next thing to do is to test the DC resistance of the power supply (test point 3). The normal resistance is also several k. If the resistance is zero, there is a DC short circuit. There are many causes of DC short-circuit, such as the short-circuit of the filter capacitor, the damage of the power oscillating tube, and the damage of the oscillation integrated block and peripheral circuit may cause short circuit. Here, it should be noted that before replacing the power oscillating tube, it must be determined that the oscillating integrated block and the peripheral circuit are normal, otherwise the power supply tube will be damaged again.

Excluding the above-mentioned problems of switching power supply , it shows that most of the faults exist in the oscillation control circuit, sampling feedback circuit or load. At this time, we should check whether the power supply circuit of the oscillating manifold is normal (test point 4). The normal voltage should be around 10V (special remind: Because the test voltage should be conducted under power, and the power board has high voltage Mains electricity, so pay special attention to personal safety, do not try to directly touch any part of the power supply). If there is no voltage or low voltage at this point, first check whether the buck resistor is damaged; secondly, check whether the oscillation integrated block and its external power supply circuit are normal. If no fault is found in the peripheral circuit, it is recommended to replace the oscillation manifold. Of course, sometimes the power supply cannot output the voltage normally, and it may also be caused by the short circuit of the load to cause power protection. For this power supply, we only need to remove the output line and check the output voltage is normal (Test Point 5) to determine the fault location. After the previous troubleshooting, the feedback circuit part should also be checked in the end. Generally speaking, this part of the fault is mainly concentrated on the optocoupler and its amplifier circuit, and special attention should be paid.

Click to view our power products

Refill Pipette Tips

Eppendorf tip refill is designed, developed and produced to perfectly match most brands of pipettes. The refill tower tip is suitable for most brands of pipetting systems to ensure pipetting accuracy. The sterile refill tower Pipette tip uses medical-grade plastic packaging to protect the Pipette Tips from contamination. The pipette tip refill is sterile, free of DNA, DNase, RNase, endotoxin or ATP. It can be autoclaved at 121 °C/250 °F (2bar) and sterilized by heat and humidity, in accordance with DIN EN 285. Environmentally friendly packaging. According to the IVD Directive 98/79, it has the European Union CE mark.

Compared with ordinary carton packaging, the refill tips system can save 60% of laboratory space and 70% of plastic. Without touching the tips, you can refill the shelf with one hand. Refill Pipette Tips can be used with universal carrier boxes.


pipette tip refill system

Pipette Tip Refill System,Pipette Tip Refills,Refilling Pipette Tips,Pipette Tip Refill,Pipet Tip Refill system

Yong Yue Medical Technology(Kunshan) Co.,Ltd , https://www.yongyuepcrtube.com