Ankerui SVC dynamic reactive power compensation and filtering device

Ankerui SVC dynamic reactive power compensation and filtering device can not only compensate the reactive power loss in the power grid by switching capacitor bank, improve the power factor, reduce the line loss, thereby improving the load capacity and power quality of the power grid; Three-phase voltage, current, power factor and other power parameters of the power grid. 1. Overview Dynamic reactive power compensation and filtering device is suitable for automatic reactive power compensation of 0.4kV frequency 50Hz voltage; it integrates reactive power compensation, China Hardware Business Network

Filtering and grid monitoring can not only compensate the reactive power loss in the power grid by switching capacitor banks, improve the power factor, reduce the line loss, thus improve the load capacity and power quality of the power grid. At the same time, it can also monitor the three-phase of the power grid in real time. Power parameters such as voltage, current, and power factor.

2, the working principle

China Hardware Business Network



3. The necessity of reactive power compensation

● If the power factor is too low, it will be punished by the power sector or even interrupt the power consumption of the enterprise.

China's power supply rules stipulate that the power factor of industrial users and power users equipped with load-adjusting voltage devices must reach 0.9 or above; for users whose power factor does not meet the above requirements, the power department will charge additional electricity charges. In accordance with the "Power Factor Adjustment Electricity Fees".

●The lack of reactive power in the power system will result in lower production efficiency and higher production costs.

When the power factor is low, the voltage of the device changes greatly, the reactive power loss is also large, and the aging of the device is accelerated, which easily causes the service life of the device to be shortened and affects the operation of the device.

● Increase the line loss of transformers and electrical network equipment

The apparent power transmitted by the line is unchanged, and the low power factor will directly increase the loss of the transformer and the transmission line, directly increasing the power cost.
4. Implementation Standard GB/T 7251.1-2005 "Low-voltage switchgear and control equipment Part 1"

GB/T 14549-1993 "Power Quality: Harmonics in the Utility Grid"

GB/T 15543-2008 "Power quality: three-phase voltage allowable imbalance"

GB/T 18481-2001 "Power Quality: Temporary Overvoltage and Transient Overvoltage"

GB/T 15576-2008 "General technical conditions for low voltage reactive power static compensation device"
5, model description
China Hardware Business Network
6. Main features ● The cabinet body adopts frame-assembled structure, surface sprayed or passivated, and the appearance is neat and beautiful, anti-aging, anti-corrosion and high life.

●The structure design is compact and reasonable, the wiring is neat and generous, and the maintenance is convenient.

● The cabinet body can be installed independently or in combination with other cabinets.

● A variety of compensation forms: three-phase total compensation, three-phase compensation, total compensation + sub-complement three forms. According to the actual situation of the power grid, taking into account the compensation effect and cost, the compensation form should be selected reasonably. Fully resolve the contradiction between compensation reactive power and three-phase imbalance and between three-phase compensation and cost.

● Use series reactors or filter reactors to suppress and eliminate the 3rd, 5th, and 7th harmonics, which can be customized according to the specific grid background of the user site.

● The controller has multi-loop loop or code switching operation mode, which can effectively avoid the problem that the individual capacitors are switched too frequently during group switching and achieve optimal control.

● With data acquisition function and standard communication interface, it can realize remote real-time monitoring and computer network management.

●The composite switch is used for switching capacitance, zero-crossing input, neither switching current and good heat dissipation mechanism, no harmonic injection, and high reliability.

● With power parameter monitoring, acquisition and statistics functions.
7, technical indicators

Technical Parameters

index

Electrical parameter

Rated voltage

AC400V

Compensation capacity

160~400kvar

working frequency

50Hz

Response time

<20ms

Overload capability

Voltage overload 1.1 times, current overload 1.3 times

Target power factor

0.8 to 1.0 (can be set)

Control characteristics

Compensation method

Total complement, sub-complement, and hybrid supplement

Number of control channels

2~18

control method

With manual and automatic switching mode

Switching algorithm

Cycling

Protective function

Overvoltage, undervoltage, phase loss, short circuit protection

Structure

Protection level

IP30 (can be customized according to customer requirements)

colour

RAL7035 (can be customized according to customer requirements)

Installation method

Indoor installation, fixed way and incoming mode

Environmental conditions

Ambient temperature

-25°C to +50°C

Relative humidity

40 ° C; ≤ 50%; 20 ° C, ≤ 90%

altitude

≤2000 meters
8, the size

Compensation capacity (kvar)

Dimensions width × height × depth (mm)

Below 100

600×2200×600

100-150

600×2200×800

150-200

800×2200×1000

200-300

800×2200×1000

300-400

1000×2200×1000

/

/

Note: This is the standard product size, the specific size can be customized.
9, application areas China Hardware Business Network

China Hardware Business Network

Technical support: Yang Junjun 18702112137 QQ
Http://news.chinawj.com.cn Editor: (Hardware Business Network Information Center) http://news.chinawj.com.cn

      Slurry Pump is a kind of centrifugal pump to transport slurry materials under the centrifugal force. It transfer the electricity energy into kinetic and position energy. The TZJE is widely applied in mine, electricity, metallurgy, coal and environmental protection for abrasive solid containing slurry transportation. It can also be used to transport some corrosive slurry with crystals.

Slurry Pump

Heavy Dutry Slurry Pump,Centrifugal Gold Mining Slurry Pump,Super Durable Centrifugal Slurry Pump,Electric Power Single Stage Slurry Pump

Shandong Hiking International Commerce Group Co.,Ltd , https://www.hikingfrp.com