High-voltage electrical operation terminology

1. Operation - The process of moving a moving contact from one position to another.

2. Split (gate) operation - the operation of switching the switch from the engaged position to the divided position.

3. Close (gate) operation - the operation of switching the switch from the sub-position to the co-location.

4. “Score” operation – after the switch is closed, the operation is performed immediately without any intentional delay.

5. Operation cycle - continuous operation from one position to another and back to the initial position; if there are multiple positions, all other positions are required.

6. Sequence of operations - a series of operations with defined time intervals and sequences.

7. Automatic reclosing (gate) operation - the sequence of operations that are automatically recombined after a predetermined time.

8. Close (on) - a combination of operations used to establish the energized state of the loop.

9. Break (break) - Used for the sub-operation of the loop when the power is on.

10. Automatic reclosing - automatic reclosing (gate) operation in the live state.

11. Opening and closing - the general term for breaking and closing.

12. Short-circuit breaking - breaking the short-circuit fault current.

13. Short circuit closing - the closing of the short circuit fault current.

14. Near-zone fault interrupt--breaking of short-circuit current in near-field fault.

15. Contact Opening Distance - The total clearance between the poles of a pole of a switch or any conductive part of the connection when sub-positioned.

16. Stroke? The distance between the starting position of the moving contact and the position of the switch.

17. Overtravel - the distance that the moving contact continues to move after the switch contacts contact during the closing operation.

18. Opening speed - the running speed of the moving contact during the switching (gate) process.

19. The distance between the contact and the static contact is the speed of the separation of the contact and the static contact.

20. Closing speed - the moving speed of the moving contact during the closing (gate) process.

21. Contact speed: The instantaneous speed of contact between the moving contact and the static contact during the closing (gate) process.

22. Breaking speed—The speed at which the moving contact moves during the opening of the switch.

23. Closing speed - the speed at which the contacts move during the breaking process.

Secondary tinplate is also well packed with sea-worthy packaging. Secondary tinpalte sheet can be cut to your length, and quick delivery with good prices.

1. Technical standard: BS EN 10202, DIN EN 10203, GB/T2520 , JIS G3303

2. Steel type: MR, SPCC
3. Thickness: 0.115 - 0.50 mm
4. Width:  600 - 1050 mm
5. Length: 600-1200mm
Tin Coating: ordinary 2.8 or 2.8g and 5.6g or 5.6g, we can produce according to customer's requests

Secondary Electrolytic Tinplate Sheet

Secondary Electrolytic Tinplate Sheet,Tinplate For Paint Can,Secondary Grade Electrolytic Tinplate Coil,Etp Electrolytic Tinplate Sheet

Jiangsu Guolian New Material Co., Ltd. , http://www.cntinplate.com